Description | Use A Static (FR4)/Soldermask Flex | Use B dynamic (PolyImide) | |
minimum plated through hole B | 0.15 mm | 0.15 mm | |
minimum pad diameter A | minimum pad diameter B + 150µm | minimum pad diameter B + 260µm | |
minimum length from plated through hole to flex | 0.8 mm | 0.8 mm | |
Copper distance to Rigiflex intersection | 350 µm | 800 µm | |
Copper distance to Rigiflex intersection | ≥ 200 µm | ≥ 250 µm | |
minimum length of flex area | ≥ 2.0 mm | ≥ 2.0 mm | |
Distance track-flex outline | ≥ 350 µm | ≥ 350 µm | |
minimum bending radius | 5 mm | 3.2 mm | |
Minimum Signal inner layer annular ring | 0.125 mm | 0.19 mm | |
Minimum distance form Rigid to Flex | 1.0 mm | 1.0 mm | |
Minimum distance from ZIF connector to Flex | > 2 mm | - | |
max. quantity of bending cycles with min. bending radius | 10 with radius 5.0 mm | 6000 s/IPC-TM-650 2.4.3 | |
Thickness of flex material | 75, 100 µm | 50 µm standard (25,75,100,125,150 on demand) | |
Cu thickness of flex layers | 17, 35 µm | 17, 35, 70 µm | |
Thickness of coverlayer IPC-4203/1 | 25 µm | 25 µm | |
Max. number of flex layers | 2 | 8 | |
General tolerances | Class 7 Lab Circuits | Class 7, Annular Ring class 5
|
|
Maximum PCB size | 530 x 400 mm | 530 x 400 mm |
Last update: 06-04-2023 Units: Milimeters |
|