| Description | Use A Static (FR4)/Soldermask Flex | Use B dynamic (PolyImide) | |
| minimum plated through hole B |
|
0.15 mm | 0.15 mm |
| minimum pad diameter A |
|
minimum pad diameter B + 150µm | minimum pad diameter B + 260µm |
| minimum length from plated through hole to flex |
|
0.8 mm | 0.8 mm |
| Copper distance to Rigiflex intersection |
|
350 µm | 700 µm |
| Copper distance to Rigiflex intersection |
|
≥ 200 µm | >= 250 µm |
| minimum length of flex area |
|
≥ 2.0 mm | ≥ 2.0 mm |
| Distance track-flex outline |
|
≥ 350 µm | ≥ 350 µm |
| minimum bending radius |
|
5 mm | 3.2 mm |
| Minimum Signal inner layer annular ring |
|
0.125 mm | 0.19 mm |
| Minimum distance form Rigid to Flex |
|
1.0 mm | 1.0 mm |
| Minimum distance from ZIF connector to Flex |
|
> 2 mm | > 2 mm |
| Track to plated through hole minimum spacing |
|
>= 250 µm | >= 300 µm |
| Crosshatched ground plane |
|
- | strongly recommended to prevent moisture entrapment and increase flexibility |
| max. quantity of bending cycles with min. bending radius | 10 with radius 5.0 mm | 6000 s/IPC-TM-650 2.4.3 | |
| Thickness of flex material | 75, 100 µm | 50 µm standard (25,75,100,125,150 on demand) | |
| Cu thickness of flex layers | 17, 35 µm | 17, 35, 70 µm | |
| Thickness of coverlayer IPC-4203/1 | 25 µm | 25 µm | |
| Max. number of flex layers | 2 | 8 | |
| General tolerances | Class 7 Lab Circuits | Class 7, Annular Ring class 5
|
|
| Maximum PCB size | 530 x 400 mm | 530 x 400 mm |
Last update: 14-11-2025 Units: Milimeters |
|